G8MNY > TECH 10.05.25 07:45z 143 Lines 6847 Bytes #63 (0) @ WW BID : 32292_GB7CIP Read: GUEST Subj: Lafayete 57 Range Multimeter Path: ED1ZAC<ED1ZAC<LU4ECL<K1AJD<VE3CGR<VK2RZ<GB7CIP Sent: 250510/0734Z @:GB7CIP.#32.GBR.EURO #:32292 [Caterham Surrey GBR] From: G8MNY@GB7CIP.#32.GBR.EURO To : TECH@WW By G8MNY (Corrections Jan 16) (8 Bit ASCII graphics use code page 437 or 850, Terminal Font) Model 99-5076 ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³³~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~³³ DC Volts 0.25 2.5 10 50 250 1000 @ 25K/V ³³ ³³ 0.125 1.25 5 25 125 500 @ 50K/V ³³ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿³³ ³³³³~~~~~~~~~~~~~~~~~~~~~~~~~~~³³³³ DC Amps 50uA 5mA 50mA 500mA 10A @ Normal ³³³³ ³³³³ 25uA 2,5mA 25mA 240mA 5A @ 2x ³Æµ³ . ³Æµ³ ÀÙ³³ '. ³³ÀÙ AC Volts 3 10 50 250 1000 @ 2.5K/V Ú¿³³ '. . ³³Ú¿ 1.5 5 25 125 500 @ 5K/V ³³³³ '. :'\': ³³³³ ³Æµ³ '. 'ú.ú' ³Æµ³ 10x dB scales & DC isolated AC. ³³³ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ³³³ ÀÙ³ÄÄÄÄÄÄÄÄÄ¿ ÚÄÄÄÄÄÄÄÄijÀÙ Ohms «FSD 13R 65R 650R 6K5 65K ³ o- +o ³ (|) ³ o o ³ ³ ³ ³ ³ Accurancy DC 2%, AC 3% ³ [± ]rev ³_________³ «[ ±] ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ MULTI METER PRINCIPLES DC VOLTS 1000 100 10 1 Volts To get a meter of just one Ú10MÄÂÄ1MÄÂ100KÂÄÄÄ11K1ÄÄÄÄ>+ sensitivity to do many o o o o ranges voltage multiplier /³\ resistors are used. Here +³ the voltage drop across /~~~\ the meter is ignored, but ³Meter³ it will affect the lowest 90uA\___/ 1V scale. ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>- Series resistors are used to protect the switch more Sensitivity is 11K1/V from high voltages. DC CURRENT 100uA 1mA 10mA 100mA For current ranges shunts +ÚÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>+ are put across the meter. /~~~\ \³/ Here the meter resistance ³Meter³ o o o o is 100R so it has 10mV drop 100uA\___/ ³ ³ ³ @ 100uA. The 1mA shunt here 10mV ³ 11R 1R 0R1 is corrected for the 100R ÀÄÄÄÄÄÄÄÄÄÁÄÄÄÄÁÄÄÄÄÁÄÄ>- meter load. AC VOLTS For AC a rectifier diode is used, & normally this alters 1000 100 10 Volts the sensitivity, so a different Ú4M5ÂÄ450KÂÄÄÄÄ45KÄÄÄÄ>~ multiplier arm the DC is used. o o o In this circuit only half the /³\ current goes through the meter +ÚÄÄÄ´<ÃÄÄ´ & the 1.1 AC sine wave form /~~~\ D1 _³_D2 factor means that 2.2x meter ³Meter³ /_\ current must flow. Only a 100uA\___/ ³100uA 100mV is lost in the germanium ÀÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄ>~ diode D1, so the low voltage range can take this into account on the scale. D2 can be any type Sensitivity is 4K5/V. & protects the low voltage D1. OHMS Here a voltage source is put in series with the meter & a known resistance that set the half scale resistance & includes (actually -ve!) the meter load resistance. ÚÄÄCal Zero RÄÄÂÄÄÄÄÄÄÄ>+ The higher the battery +³ \³/ voltage the higher resistance /~~~\ o o o o that can be measured, but ³Meter³ Ú10Á100Á1KÁ10KÙ becomes a danger for 100uA\___/ ³ sensitive electronics. ³ ³ ³+ The Cal zero R sets the meter ÀÄÄÄÄÄÁÄÄÄÄÛÃÄÄÄÄÄÄÄÄÄÄ>- sensitive to give full scale ³ (actually +ve!) ZERO reading on shorting the probes depending the battery state. Note that the battery internal resistance is added to the unknown resistance, & this affects the low range scale calibration! Also the probe polarity is reversed to that indicated & it is different than for digital meters! ACTUAL MULTIMETER CIRCUIT ÚÄ=========================================================================== ³ I ³Ú========================= =============== ================ =========== =¿ \/ ÀÄ20KÄÄ80KÄ¿ ³ ³ ³ /\ /³\ ³ ³ ³Com + 10A O/P³ ³ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ ³ ³ ³ o o o o ³ ³ ____ ÚÄ¿ ³ ÚÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÁÄÄÂÄÄ)ÄÄÄÄÄ)ÄÄ´ ³u1³ ³ ³ ³ /15uA\ ³ ICal ³ ³ 13 ³ Low ³ 13K ÚÄ)ÄÄ)ÄÄÁ´Ã)ÄÄÙ ³ ³ Ú´ Meterô ÃÄÄÄÄÄÄÄ)Ä)Ä¿ ³ 46K Ú4K7´<ô ³ ³ ³ ³ ³ ³ ³ ³ \____/ ³12K5 ³ ³ ³ ³ ³ oNor³ 3K3 ³ ³ ³ À0R025´ ³ ³ ³ ³ ³ o o ³ ³ ³Ú> ³ ³ ³ ³ ³ ³ ³ ³ ÃÄÄ´>ÃÄÄÄ´ ÀoNor Ú> X <Ù ³ ³³ o« ³ 5kHi³ ³ ³ ³ ³ ³ ÃÄ´<ÃÄÄÄÄ´ <ÄÄÄ´ o o ³ ³³ À4K7Á´>ÃÁÄÄÙ ³ ³ 0R475 ³ ³ ÃÄÄVCalÄÄÙ ÚoVA/2³Rev Nor ³ ³³ Low ³ ³ ³ ³ ³ ÀÄÄÄÄÄÄÄÄÄÄÁÄ6K25Ù Ú)ÄÄÄÄÄÄÄÄÄÄÄÄÄ))ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´ ÀÄÄÄÄÄÄÄÄ)¿ ³ ³ ³³ ³³ ³ ÚÄÄÄÄÄÄÄÄÙ³ ³ ÀÄÂ56K25Â197K5Â1MÂ5MÂ18M75¿³Ã47Â650Â6K54¿Ú´³Ú1M87ÂM5ÂM1Â17K5´ Ã4R53Â45R3Å24K9´ o o o o o o³o o o o³o³o o o o o´ o o o o ³ I ³ ³ ³ =========================Ù=============Ù À================ÃÄ================ I ³ ===============¿____³Ü³Ü________³ +³ß³ß 0.25 2.5 10 50 250 1k R/5 R 10 100 1k 1k 250 50 10 3 500 50 5 50u \________DC_VOLTS_________/ \_____OHMS____/ \___AC_VOLTS___/ \____DC_mA____/ & dB Scales The configuration switching between modes & all the ranges is all done on just 1 large rotary switch with 3 bridging contacts (I) & 5 wipers of 2 circuits. Only 4 probe sockets are used, 2 extra for the high current (10A) & the DC isolated AC measurement. Extra switches provide a meter reverse feature & a double sensitivity that doubles the number of meter ranges. (has no meaning on ohms!) This meter's movement is a extremely sensitive @ 15uA for FSD, but not very accurate, so it is calibrated with an ICal & VCal presets at manufacture. The AC ranges are calibrated with select on test resistors 2x "4K7 Low" & the "5K Hi" that accurately allows for the diode forward resistance loss & leakage. Most of the resistors are special values made for the meter, & of course they are very accurate & stable 0.5% types. See my tech buls on "Meter Movement Types", "Maplin Mains Meter 2000MU-UK", "Edgcume Peebles Megger & Low R", "Edgcume Peebles Earth Loop Z", "Car Dwell Angle & RPM Meter", & "Kelvin Varley Voltage Divider". Why don't U send an interesting bul? 73 De John, G8MNY @ GB7CIP
Read previous mail | Read next mail