G8MNY > TECH 05.06.25 08:45z 75 Lines 3618 Bytes #96 (0) @ WW BID : 34099_GB7CIP Read: GUEST Subj: Rotator Alinco info Path: ED1ZAC<ED1ZAC<GB7CIP Sent: 250605/0835Z @:GB7CIP.#32.GBR.EURO #:34099 [Caterham Surrey GBR] From: G8MNY@GB7CIP.#32.GBR.EURO To : TECH@WW By G8MNY (updated Aug 17) (8 Bit ASCII graphics use code page 437 or 850, Terminal Font) This is basic & reliable rotator with manual switch controls & regulated meter heading readout. ___________ ___ /ºº\ Stub Mast ³ ÚÄÄÄÄÄÄÄ¿ ³ \ ³ ºº ³ Clamp Castings ³ ³ .-"-. ³ ³ \ _³_ºº_³_ ³ ³'_____`³ ³ ³ / \ ³ 0 ³ ³ 6 Wire ³__________³ ROTATOR 2 drilled ³ --------- ³ ³ Cable ³________³ steel strips ³ ³o³ [I] ³ _.Ù ³ ºº ³ À option flat ÚÄÄÄÄÄÄ¿ ³___________³_.-' Support ³ ºº ³ base plate / /P Cow \ CONTROLLER Mast Clamp \ºº/ remove clamp /field feet\ For /P use cow field feet strips, then a 66ft mast can be put on top of it with a 3el HF TH33 & 5el 6m beam etc, without the rotator spinning on the ground. DIAGRAM LÄoÄÄoÂÄ¿ ÚÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄ8RÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 6 *ÄÄÄÄÄÄÄ¿ Fuse³ )º( ³ ³ added AC Common ³ 240V³ )º( ³ ³ ³ 0.5u=== )º( 24V ³ 33R Left 2x8R ³ added³ )º( ³ ³ ÚÄo\ oÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 5 *Ä())))Ä´ ³ )º( ³ ³ ³ ===130uF AC ===== ³ NÄo/'oÁÄÙ ÃÄÄÄÄÄ)ÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÄÁÄo/ oÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 4 *Ä())))ÄÙ ON ³ ³ _³_ Right MOTOR ³ 120R \_/ ³added³ ÃÄÄÄÂÄÄÄÄÄ¿ ³ ³ ³ 470R ³/' 8.5V ³ ³ ³ ÃÄÄÄ´ REGULATOR added ³ ³ ³ ³ ³\e FB3,, ³ ³ ³ ³ ÀÄÄ100RÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 2 *ÄÄÄÄ¿ ³ LAMP +³ ³ ³ _'' ³ ³ ³ === ÃÄÄÄ¿ 10n=== /~ ~\ CAL ROTOR ³ ³ 470u³ _³_ `\³ ,, ÃÄÄ´MeterÃÄÄ8KÄÄ* 3 *ÄÄ>POT ³ ³ ³ '/_\ ÃÄÂÄÄÄÄÄÄ´ -\._./+ PRESET 500R ³ ³ ³ 9V³ e/³ ³ ''FB ³ ³ ³ ³ ³ ³ ³ ===1n 27R ,, ³ ÀÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 1 *ÄÄÄÄÙ CURRENT LIMITER FB2'' added * = External Connection N.B. *1* to *6* = 24V AC could be useful for things! The circuit could have been wired to use only 5 wires if the switch feed & AC common were reversed, making 1 the new AC common to the motor, as well as the pot earth. MODS 1/ As with most rotators the motor is well over run, so if high usage (eg. more than 2 mins) is needed, then add a high wattage low value R (eg. 8R 10W) in series with the motor common (*6*). This will increase motor run time before it overheats, without significantly reducing the available torque. 2/ Under running the lamp with 120R in series will increase its life. Silver foil the meter sides, & paint the top of the lamp white, this makes the lamp as bright as before & with less shadows. 3/ Also a 0u5 250V AC Cap across the mains will correct the transformer's power factor for /P operation (but not the motor run PF!). 4/ QRO on lower HF bands gets into the current limit transistor & reduces the meter reading, as a single FB on the base is not enough. FB2 has 5 turns & is in the cut PCB track. FB3 is just on the lead. Why Don't U send an interesting Bul? 73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail