G8MNY > TECH 10.04.25 09:15z 87 Lines 4332 Bytes #115 (0) @ WW BID : 29991_GB7CIP Subj: Eagle DB120 Sound Meter Path: ED1ZAC<ED1ZAC<LU4ECL<JE7YGF<JH4XSY<N3HYM<VE3CGR<VK2RZ<GB7CIP Sent: 250410/0901Z @:GB7CIP.#32.GBR.EURO #:29991 [Caterham Surrey GBR] From: G8MNY@GB7CIP.#32.GBR.EURO To : TECH@WW By G8MNY (Correction Feb 16) (8 Bit ASCII graphics use code page 437 or 850, Terminal Font) The is a simple cheap sound meter. ____ PCB LAYOUT ÚÄÄÄÁÄÄÄÄÁÄÄÄ¿ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³³~~~~~~~~~~³³ ³ /~~~\ ³ ³³ \ ³³ ³Q12³METER³VR2³ ³³ \ ³³ ³ \___/ ³ ³³__________³³ 40dBA-120dBA in 2 ranges ³ ³ ³ ____³ In built calibrator ³VR1 __ ³ ³ /~~\ ³ ³Ú¿ Q5 /~ ~\³ ³ ³ ³³ ³³³ ³SWITCH³ ³ \__/ ³ ³³³IC \_ _/³ ³ ~~~~³ ³ÀÙ VR3 ~~ ³ ³ ³ ³ ³ ³ EAGLE ³ À¿ ÚÄÄÄ¿ ÚÙ ³ ³ ³VR5³ ³VR4³ ³ ³ ÀÄÄÄÙ ÀÄÄÄÙ ÀÄÄÄÄÄÄÄÄÄÄÄÄÙ CIRCUIT ÚÄÄÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÄ2K2ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÂÄ<+ve ³ 56K ³ ³ ³ ³ OPAMP ³ + ³ ³/ ³+ ³ ³ The TD7120 provides MicÄ´ÃÄÅÄ´Q3 === ³ 56K fixed stable gain ³ 4u7 ³ ³\e ³33u 7³ ÚÄÄÄ¿ ³ to drive the non the ³ 56K ³ ³ Low 2³~\³3 56K ³ linear metering stage. ³ ³ VR2ÃÄ)ÄÂÄÄÄÄÄÄÄo<Ä2K2ÄÄÂÄÄÄ´TA\ 6³ ³ + ³ ³ Mic ³14K4 150K ³7120>ÄÁÄÄÄÄ)ÄÄ´ÃÄÄ3K3Ä> ³ ³ cal ³ ÃÄÄÄÄÄÄÄo ÃÄÄÄ´ /ÀÄÂÄ19KÄ´+ 10u ³ ³ ³ ³220R High +³ 5³_/ 1 ³ === ³ ³ ³ ³ ³ 10u=== ³4 ===3n3 ³10u ÀÄÄÄÄÄÁÄÄÄÁÄÄÄÁÂÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÁÄÄÄÄÁÄÄÄÄÄÁÄ< ÀÄÄVR1ÄÄÂo Cal 200R ³ ÚÄÄÄÄÂÄÄÄÂÄÄÄÄÂÄÄ5K1ÄÄ<+ve 220K ³ 33K 33K ³ PREAMPS ³ 3K9 ³ ³ 3K9 The 3 wire electret mic ÀÄÄÄÄÅÄÄ´ÃÁ\ /Á´ÃÄÄ´ & preamp Q3 is powered \³ X ³/ from a decoupled rail. Q2ÃÄÄÄÙ ÀÄÄÄ´Q1 e/³ ASTABLE ³\e VR2 calibrates the mic ÀÄÄÄÄÄÄÂÄÄÄÄÄÄÙ capsule & VR1 calibrates 100R the astable calibrate ÄÄÁÄÄÄ< oscillator Q1&2. METER DRIVER oOff +ve<ÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄ¿e ÚÄÄÂÄÄÂÄo<ÄÄÄÂÄÄ¿ 10K ³/ 47u³+ \ / 2K2 ÃÄoHigh³ ³ ÃÄÄ´Q5 === ÄÄÂÄÄ ³ ÀÄoCal ³ ³ _³_ ³\e +10u ³ Q7ÃÄÄÄÄÙ ÚÄoBat ³ ³ \_/ ÃÄÄÄ560RÄÄÂÄ´ÃÄÄÂÄÄÄ¿ ³ ³ ³ oOff³ ³ _³_ ÃÄÄ¿ +³ ³ ³ ³ ³ ³ ³ ³ D1 \_/ ³/e ³ ===10u ³ ³ ³ _³_ ³ ³ ³ ÚÄ´>ÃÄ¿ ÃÄÄ´Q6 100K ³ ³ ³ ³ /_\' ³ === ³+ ³ ³ ³/ ³\ ³ ÚÄÁÄ¿ ³ ³ ³ ³ ³ ³ BATT >ÄÅÄ2K2ÄÅÄÄÂÄÄÄ´Q4 ³ ³ _³_ _³_ _³_ _³_ ³ ³ ³ ³ PP3 ³ ³ 100k ³\e ³ ³ \_/ /_\ \_/ /_\ ³ ³ ÃÄÄÄ¿ ³ ³ ÀÄ´<ÃÄ´ ÀÄÄÄÄÄ)ÄÄÄÄ)ÄÄ´+ ³D9 ³D8 ³D7 ³D6³ ³ VR3 680R³ ³ D2 ³ 220R ³ === ³ ³ ³ ³ ³ ³ 50K ³ ³ ³ ³ ³ ³ ³10u ³ ³ ³ ³ ³ ³ ³ ³ ³ ³ <ÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÂÄÁÄÄÄÄÁÂÄÁÄÄÄÄ)ÄÄÄÁÄÄÄÁÄÄÄ)ÄÄÁÄÄÄÄÁÄÄÄÄÄÄÄ)ÄÄÄÁÄÄÁÄÄÙ ³ 10u=== ===10u ³ ³ ³ D3ÃÄ´<ÃÄÄÁÄÄVR5ÄÄÁÄÄÄÄÄÄÁÄÄÄ´>ÃÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄ´ ³ 5K D10 ³ VR4 33u=== Meter D4ÀÄ´>ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄ2KÄÄÄÄÄÁÄÄÄÄÄÙ To get a usable 40dB scale on a meter quite a lot of compression is needed. This circuit uses an AGC approach. Transistors Q4, 5 & 6 from a power amp to drive the double voltage doubler bridge D6-10 rectified load of the meter & also provide AGC with D3 & D4 making an variable input attenuator. VR5 set the AGC log action & diodes D1 & D2 correct for over compression to get the very linear 40dB scale. VR4 is the main calibrate & VR3 is the battery cal. See my bul on "Sound Levels dBA dBB dBC". Why don't U send an interesting bul? 73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail