G8MNY > TECH 08.04.25 09:15z 72 Lines 3207 Bytes #17 (0) @ WW BID : 29834_GB7CIP Read: GUEST Subj: Drake WH7 QRO HF SWR Bridge Path: ED1ZAC<ED1ZAC<GB7CIP Sent: 250408/0906Z @:GB7CIP.#32.GBR.EURO #:29834 [Caterham Surrey GBR] From: G8MNY@GB7CIP.#32.GBR.EURO To : TECH@WW By G8MNY (New Nov 06) (8 Bit ASCII graphics use code page 437 or 850, Terminal Font) I have reverse engineered this QRO Bridge. It was quite straight forward. SPECIFICATION Ú==================¿ Frequency range 1.8-54MHz ³ ÚÄÄÄÄÄÄÄÄ¿ ³ Impedance 50R ³ ³ \ ³ o ³ Peak Power 2kW ³ ÃÄÄÄÄÄÄÄÄ´ _ ³ Connection SO239 ³ ~~~~~~~~ <_> ³ Accuracy ñ(5% of reading +1% of full scale) ³__________________³ VSWR Insertion 1.05:1 ß ß THE CIRCUIT --------- HEAD UNIT ------- XMTR o)ÄÄÄÄÄÄÄuÄÄÄÄÄÄÄÂÄÄÄÄ(o LOAD ÃÄÄÄÄ======= C1³/\ ³ ³ T1 ()))))) === ³ ³ ³ ³ ³ /'³ ³ ÃÄ´ÃÄ)ÄÄÁÄÄ)ÄÄÂÄÁÄ´ÃÄ´ ³n15 ÃÄ68RÄ´ ³ n15 ³ ³ _³_ _³_ ÀÄ2K2ÄÄ´ ----------- METER BOX ------- ³ D1\_/ \_/D2 ³ wh R \~ ~ ~ ~ ~ ~ \ ___ 200uA ³ ³ ÃÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo \ VAR Úo \ +/SWR\640R ³ ³ ³ ³ bn <ÄÄoÄ68KÄÄ´ <ÄÄoÂÄ<Meter>¿ ³ ÃÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄo SWRÀo ³ \___/ ³ ³ ³ ³ ³ gn F À´ÃÄÄÄÄÄÄ´ ³ ÃÄ68KÄ)Ä20KPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo 10n ³ ³ ³ ³ ³ bl 2000W ³ ³ ÃÄ10KÄ)Ä20KPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo ³ ³ ³ ³ ³ rd 200W ³ ³ ÃÄÄÄÄÄ)Ä10KPreÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄo ³ ³ 1n=== ===1n ³ bk 20W ³ ÀÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ HOW IT WORKS A short length of thick wire goes through the screened ferrite transformer T1 making a 1 turn primary, & the lead joins the XTMR & LOAD sockets together. A pickoff voltage attenuator is formed with trimmer C1 & the 2 150pF caps. This RF voltage is fed to T1 secondary centre tap. Load current is transformed by T1 into a voltage across the 5W non inductive 68R. When the load is exactly 50R, diode D2 sees no RF, as the voltage sample & the current sample are in opposition & cancel dependent on the calibration of the trimmer C1. The 2K2 is needed to complete the DC meter circuit & will affect the calibration of the lowest frequency, as will the L value of T1. Diode D1 however sees the voltage tap & the current sample added together & produces DC across the 1nF, & feeds this to the meter box on the brown wire for SWR full scale, & via the calibration power presets on green, blue & red wires. SWR voltage readings will be present on D2 when the load is not exactly 50R are fed out on the white wire. The meter box has a 1 wafer switch that forms a 2 switch bank connected as show, to give all the functions. See also my Tech buls on "A Homebrew HF SWR Bridge", "PEP Meter modification", "QRP SWR Bridge", "Meter Damping & Speed Up" & "Palstar AT1500CV ATU", "HF ATU & SWR Bridge VC300LP/QT-1" Why Don't U send an interesting bul? 73 de John, G8MNY @ GB7CIP
Read previous mail | Read next mail