G8MNY > TECH 20.04.25 08:15z 107 Lines 5436 Bytes #181 (0) @ WW BID : 30702_GB7CIP Read: GUEST Subj: HONDA Generator EX500 info Path: ED1ZAC<ED1ZAC<IZ3LSV<I0OJJ<GB7CIP Sent: 250420/0800Z @:GB7CIP.#32.GBR.EURO #:30702 [Caterham Surrey GBR] From: G8MNY@GB7CIP.#32.GBR.EURO To : TECH@WW By G8MNY (Updated Aug 08) (8 Bit ASCII graphics use code page 437 or 850, Terminal Font) A few years ago, I was given one of these small old 4 small stroke petrol generators with no information. It would not start (hence it was given away less loads of screws!), but I managed to trace the cause to a completely blocked main carburettor jet, after a major strip down to get at the bits and several goes at gently cleaning the jet (not to enlarge the hole it) it now runs OK. .ÄÄÄÄÄÄÄÄÄÄÄÄÄ. BreatherÚÄ¿ .ÄÄÄÄÄÄÄÄÄÄÄÄÄ. / /~~~~~~~~~~~\ \ Handle³ ³ Filler / /~~~~~~~~~~~\ \ .ÄÄÁÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÁ, LowÚÄÄÄÄÄÄÁÄÁÄßßßÄÄ¿Trips ,ÁÄÁÄÄÄÄÄÄÄÄÄßßßÄÁÄÁÄÄ. ³ ____ Þ oil³ [] ÚÄÄÄ¿ o | ³run Þ ³ ³ ³Í¸¿ ³ Ý Hz³ Ú¿ ³_"_³ o ³ ³ Ý Speed(O) ³ ³ ³____³ Þ Ind³ ÀÙ ÀÄÄÄÙ[_] Ï ³off =Þ ³ ³ Plug ³ ³~ ~ ~AC~ DC ~ ~³ ³ ³ ³ ÿPull ³ Ú¿ ³ Ú´ ÚÄÄÄ¿ ³ ³ Exhaust(o) ³³Start ³ ³³ ³ ³³ Oil³ 0 ³ ³ ³ ÃÙ ³ ÀÙ ³ À´ o Earth ÀÄÄÄÙ ³ ÀÂÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÂÙ ÀÂÄÂÄÄÄÄÄÄÄÄÄÂÄÂÙ ÀÂÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÂÙ ~ ~ ~ Feet ~ ~ ~ But when I laid it up for a while, it can be difficult to start (carburettor not emptied), I found that putting a few CCs of petrol into the carburettor intake fixed that (or using a "Cold Start" Ether spay), as dried up petrol is less volatile. CONTROLS It could not be simpler, the RUN/OFF leaver operates the engine kill switch and the double petrol & vent tap. There is a bimetallic operated choke, so nothing to do other than pull hard on the start cord handle. If the engine has low oil then the warning light lights. RATING In the 50Hz low rev quiet & economy mode, it gives 330VA, 400VA MAX, or set to the noisier higher reving 60Hz it gives 400VA, 500VA MAX, this is also the "Lamp" mode to reduce 25Hz content of the 4 stroke, that makes lamps flicker, e.g. 1 power BANG in 4 half wave load cycles. BANG /~\255V _._225V /~\BANG _._ / \ / \ / \ / \ ³ ³ ³ ³ ³ ³ ³ ³ ³ High \ / \.__./ \ / \.__./ Volts ~~ 240V 210V ~~ 55Hz 52Hz 49Hz 46Hz Fast Slow Generators with a much heaver flywheels tend to suffer less from this. It also has 12V 100W charging output, which is 20V with no load, & 6-8A typical unregulated charge current, but it is connected to the 220V output! ECONOMY It is also VERY economical if you don't need high power. e.g. it can run some small fluorescent lamps, a rotator and float a 12V battery with 100W HF rig OK, for some 6 hours from 1 fill of its small 2.5L tank. So 1 gallon per day is feasible when /P for 12 hours/day operating. CIRCUIT I have reverse engineered the diagram & it is very complex for such a small unit! ON LampÄÄÄÂÄÄÄÄÄÄE CHARGING ______ ³ ³ 13A S/O +ÜÜ DCÞ- ___o ³Push ³TuningÃÄÄÄ)ÄÄÄÄ´ N L ³ ³ _³_ o ³OFF ³Forks ÃÄÄÄ´ gn³ ³ rd³ Trip ³ ³ ³Hz Ind³ ³ /ye³ ³bl ³ 10A ³ ³ ÀÄÄÄÄÄÄÙ gy³ ³ ³ Trip ³ bk³ ³bk/rd Oil LampÄÂÄÄÄÄ´ ³ ³ 3A ³wh ³ ³ Left Alt ye³ ³gy Ø Ø Ø Ø Ø Ø ³ Module Ø Ø ³ ³ ³ ÀÄÄÄÄ)ÄÄÄÄ)ÄÄÄÄ¿ ³ ÚÄÄÄ¿6 pole Alt ³ ³ ³ ³ ³ ÚÄÄÄÄ)ÄÄÄÄ´ ³rd Ø ³ ÃÄ×ÄÄÄ¿wh ³ ³ ³ ³ ³ _³_ ³ _³_ ³ ³ ³ ³ 28R) ³ ³ ³0.6R³ ³18R \_/ 1R³1R \_/ 2R³ bk³ ³ ÃÄ×ÄÄÄÙbk ³ ³ À((((´ À((((ÄÁÄ(((Á(((ÄÁÄ(((´ ³ ³A ÃÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄ)ÄÄ)ÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ³ ³ ³ ³ gn Feedback ³ ³ ³ Main 2 pole Alternator ³ ³ ³V ÃÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄ)ÄÄ)ÄÄÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ___ ³ ³ ³ bl \ \ gnÃÄÄÄÄÄÄÄÄ(((((ÄÄÄÄÄÄÄÄÄÄÄÄÄ´SCRÃÄÙ /Stark ³R ³ r/w 50Hz \ \ _³_ 430R bk/rd ³IGN³ 10k³ Plug ³ ÃÄ×ÄÄ)))))Ä×ÄÄo \ \ ______ bn ³ ³bk/wh )| ³ ³ ³ ye ÀÄ×Äo \__ \ \_ÚÄÄÄÄÄÄ¿bl ³TimingÃÄ×ÄÄ´ ÃÄÄ×ÄÄÄ)| ³ ³ ³ ye bk/w 60Hz³ \___³EngineÃÄÄÄÄo ³Head ÃÄÄ×Ä´ ³ 1R)| ³ ³ ÃÄ×ÄÄÄÄÄÄÄ×ÄÄÄÄÄÄÙ ÚÄ´ModuleÃÄÄÄo/ ³ 73R ³ ye ÀÄÂÄÙ ÀÄÂÄÙ ÀÄÄÄÙ op-gn y/r _³_ÀÄÄÄÄÄÄÙbl Oil ÀÄÄÄÄÄÄÙ _³_ _³_ Switch × or Ø are connectors. DC USE Note, the DC is connected to the 230V! So the 230V will no longer be floating safely, if it is used with the DC output at the same time! See my bul on "Regulating 12V genny output" for the circuit that I use with it. MODS From my long bul "Petrol generators for SSB use", I did the Rev up feed forward modification, and it did slightly improve voltage regulation under load. I also did the ignition QRM mods, & fully suppressed this generator. Y Don't U send an interesting bul? 73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail