G8MNY  > TECH     21.03.26 11:04l 72 Lines 2580 Bytes #60 (0) @ WW
BID : 55054_GB7CIP
Subj: Rig DC Power & RF Hazards
Path: ED1ZAC<ED1ZAC<GB7CIP
Sent: 260321/0948Z @:GB7CIP.#32.GBR.EURO #:55054 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To  : TECH@WW

By G8MNY                                          (New Feb 12)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)

With connection to add ons to to your rig there is a hazard that can burn out
or dammage ground wiring in your... PC, Noise Eliminating LS, Preamps
Powered Auto ATUs, and rotators etc.

The cause is high DC or RF currents being allowed to flow over signal leads
cause by faulty earths and earth loops.


    ÚÄÄÄÄÄÄÄÄ¿ +        20A 
    ³        ÃÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿       In this example the
    ³ Power  ³     ³            ÚÄÁÄ¿     the rig is earthed only
    ³        ³  ÚÄÄÁÄÄ¿ LS lead ³   ³     via the LS.
    ³ Supply ³  ³NoiseÃÄÄÄÄÄÄÄÄÄ´Rig³       Damage can be to..
    ³        ³  ³ LS  ÃÄÄÄÄÄÄÄÄÄ´   ³         Rig LS socket wiring,
    ³        ³  ÀÄÄÂÄÄÙ         ÀÄÂÄÙ         Rig PCB,
    ³        ÃÄÄÄÄÄÁÄÄÄÄÄ//ÄÄÄÄÄÄÄÙ           LS lead,
    ÀÄÄÄÄÄÄÄÄÙ -      Failed/poor             Noise LS PCB,
                      Rig Earth               Noise LS Power lead.

Using no PSU earth connection and only earthing via the rig connection is a
possable cure for low current accessories.

    ÚÄÄÄÄÄÄÄÄ¿ +        20A
    ³        ÃÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
    ³ Power  ³     ³            ÚÄÁÄ¿
    ³        ³  ÚÄÄÁÄÄ¿ LS lead ³   ³
    ³ Supply ³  ³NoiseÃÄÄÄÄÄÄÄÄÄ´Rig³
    ³        ³  ³ LS  ÃÄÄÄÄÄÄÄÄÄ´   ³
    ³        ³  ÀÄÄÂÄÄÙ         ÀÄÂÄÙ
    ³        ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
    ÀÄÄÄÄÄÄÄÄÙ -

In the next example there is both DC & RF problems.

    ÚÄÄÄÄÄÄÄÄ¿ +   20A
    ³        ÃÄÄÄÄÄÄÄ¿  \³/
    ³ Power  ³     ÚÄÁÄ¿ ³
    ³        ³     ³   ÃÄÙ       ÚÄÄÄÄÄÄ¿
    ³ Supply ³     ³Rig³ AF Lead ³Laptop³ VGA Lead ÚÄÄÄÄÄÄ¿
    ³        ³     ³   ÃÄÄÄÄÄÄÄÄÄ´      ÃÄÄÄÄÄÄÄÄÄÄ´SCREEN³
    ³        ³ -   ÀÄÂÄÙ         ÀÄÄÄÂÄÄÙ          ÀÄÄÂÄÄÄÙ
    ³ Ú------ÃÄÄÄÄ//ÄÙ             ÚÄÁÄ¿No DC         ³
    ÀÄÂÄÄÄÄÄÄÙ Failed/poor         ³PSU³earth       MAINS
    MAINS       Rig Earth          ÀÄÂÄÙ            Earth
    Earth                          MAINS

  DC can dammage...
    PSU earth wiring and Mains lead,
    Rig AF socket/PCB,
    AF lead, Laptop mother board,
    VGA lead, Screen, and Screen power lead.
  
  If there is no DC fault but RF voltage on the rig, RF currents can damage..
    Rig AF socket/PCB,
    AF lead, Laptop mother board,
    Latop PSU's mains RF filter,
    VGA lead, Screen.


See my Tech Buls on "BHI Noise Eliminating DSP LS", "A Simple V.O.X. Circuit",
"PSK31 interface isolation".
 
Y Don't U send an interesting bul?

73 de John G8MNY @ GB7CIP